ATP Fluorescence Detector Bacteria Microorganism E. Coli Detection Meter For Sale

ATP Fluorescence Detector Bacteria Microorganism E. Coli Detection Meter
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Buy Now

ATP Fluorescence Detector Bacteria Microorganism E. Coli Detection Meter:
$689.93

ATP Fluorescence Detector Touch Operation Handheld Fluorescent Detection Meter

Introduction:

The device is a new upgrade product, Android smart operating system. The operation adopts the biochemical reaction method to detect the ATP content. The ATP detector is based on the principle of firefly luminescence and uses the \"luciferase-luciferin system\" to rapidly detect adenosine triphosphate (ATP). The ATP swab contains a reagent that can lyse the cell membrane, which can release the intracellular ATP, react with the specific enzyme contained in the reagent, and generate light, and then use a fluorescence illuminometer to detect the luminescence value. The number of microorganisms is proportional to the luminescence value. Since all living cells contain a constant amount of ATP, the ATP content can clearly indicate the amount of microorganisms and other biological residues in the sample, which can be used to judge the health status.

Application:

Hengmei ATP detector is widely used in: bacterial and microbiological testing, medicine and hygiene, food safety, market law enforcement, surface cleanliness testing, medical and epidemic prevention, water quality and water administration, production line hygiene, industrial water treatment, environmental protection testing, customs entry-exit quarantine and other law enforcement sectors and other industries.

Software platform:

The instrument also has wifi networking function, bluetooth transmission, data cable connection to the computer and multiple uploading methods, and is equipped with an online monitoring platform, historical data can be wirelessly uploaded to the software platform for historical data analysis and statistics. Historical data can present curve trend graphs, pie charts, etc. The user\'s health monitoring and plan management can be realized through the platform. At the same time, it can upload the mobile terminal point-to-point instantaneously in the form of excl, which is convenient for mobile phones to share reading data.

Features:

Practicality -- The upper and lower limit values ​​can be set according to the needs of environmental testing, so that the data can be quickly evaluated and early warning, and the surface cleanliness can be quickly screened.

High sensitivity -- 10-15~10-18 mol

Fast speed -- conventional culture method takes more than 18-24 hours, while ATP only needs ten seconds.

Feasibility -- There is a clear correlation between the number of microorganisms and the ATP contained in the microorganisms. By detecting the ATP content, the number of microorganisms in the reaction can be indirectly obtained

Operability -- The traditional culture method needs to be operated by trained technicians in the laboratory; while the ATP rapid cleanliness test is very easy to operate, and it can be operated by general staff on site with only simple training.

Better experience -- The test tube adopts a plug-in flexible design, which can be cleaned regularly for long-term use and prolong the life of the instrument.

Strong interactivity -- Android high-sensitivity touch operation, high-speed data processing chip, faster running speed and stronger stability.

Main parameters of ATP detector:

1. Operating program: Android system, can switch between Chinese and English

2. Display screen: 3.5-inch high-precision graphic touch screen

3. Processor: ARM Cortex-A7, main frequency 1.88Ghz, 4-core high-speed chip

4. Detection accuracy: 1×10-18mol

5. Coliform: 1-106cfu

6. Detection range: 0 to 99999 RLUs

7. Detection time: 15 seconds

8. Detection interference: ±5% or ±5 RLUs

9. Operating temperature range: 5°C to 40°C

10. Operating humidity range: 20-85﹪

11. ATP recovery rate: 90-110%

12. Detection mode: RLU, coliform screening

13. Data storage: 4G memory can store 100,000 pieces of data

14. 50 user ID settings

15. The number of result limits that can be set: 251

16. Automatically judge qualified and unqualified

17. Automatic statistical pass rate

18. Built-in self-calibration light source

19. Self-check for 30 seconds after booting

20. Equipped with miniUSB interface, the results can be uploaded to PC

21. With wifi, bluetooth transmission function, the results can be uploaded wirelessly to the data analysis platform

22. Equipped with special software driver U disk instead of traditional CD

23. Instrument size (W×H×D): 188mm×77mm×37mm

24. Use rechargeable lithium battery without battery replacement

25. Standby state (20℃): 6 months

26. Chinese and English operation manual

27. Stable liquid luciferase

28. Wetted integrated collection swab



Buy Now