Fluke 18B+ Plus AC DC Voltage Current Digital Multimeter DMM with LED
Feature:Faster response
Greater capacitance range: 0.01nF ~ 1000μFThe more bright: Add white LED backlightLarger screen: Larger than the original 1.5 times Frequency & duty cycle Auto/Manual range Max/Min value 600 V CAT III 1000V CAT.IISpecifications:

Display

4000counts

LED test

Yes

Auto/Manual range

Yes

Data hold

Yes

Diode test

Yes

Continuity

Yes

Auto power off

Yes

Specifications

Function

Range

Accuracy

Voltage DC

0.1mV~1000V

± (0.5%+3)

Voltage AC(40Hz~500Hz)

0.1mV~1000V

± (1.0%+3)

Current AC(40Hz~200Hz)

0.1uA~10A

± (1.5%+3)

Current DC

0.1uA~10A

± (1.5%+3)

Resistance

0.1Ω~40MΩ

± (0.5%+2)

Capacitance

0.01nF~100uF

± (2.0%+5)

LED test

2~6V DC

10%

Mechanical & General Specifications

Size

180 x 89 x 51.5 mm

Weight

425g (battery included)

Battery

2x AA 1.5V

CAT class

CAT.III 600V CAT.II 1000V

AC and DC Voltage

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

AC Volts

(40Hz-500Hz)[1]

4.000V

40.00V

400.0V

1.0 % + 3

1.0 % + 3

1.0 % + 3

AC Millivolts

3.0 % + 3

3.0 % + 3

3.0 % + 3

DC Millivolts

1.0 % + 10

1.0 % + 10

1.0 % + 10

DC volts

4.000V

40.00V

400.0V

0.5 % + 3

0.5 % + 3

0.5 % + 3

[1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.

AC and DC Current

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

AC Current μA

(40 Hz-400Hz)

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

1.5 % + 3

1.5 % + 3

AC current Ma

(40Hz – 400Hz)

40.00 m

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

1.5 % + 3

1.5 % + 3

AC current A[1]

(40Hz – 400Hz)

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current μA

400.0 μA

4000 μA

0.1 μA

1 μA

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current mA

40.00 mA

400.0 mA

0.01 mA

0.1 mA

1.5 % + 3

1.5 % + 3

1.5 % + 3

DC current A[1]

4.000 A

10.00 A

0.001 A

0.01 A

1.5 % + 3

1.5 % + 3

1.5 % + 3

[1] 10 A duty cycle < minutes on, 20 minutes off.

Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle

Function

Range

Resolution

Accuracy

15B+

17B+

18B+

Diode Test[1]

2.000V

0.001V

10 %

Temperature

0.1°C

NA

2 % +1°C

2°C

9% +2°C

NA

Resistance

400.0 nF

4.000 μF

40.00 μF

400.0 μF

1000 μF

0.01 nF

0.1 + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

2% + 5

2% + 5

5% + 5

5% + 5

5% + 5

5% + 5

Frequency[3]

(10Hz -100kHz)

Hz

50.00 Hz

500.0 Hz

5.000 kHz

50.00 kHz

100.0 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

Duty Cycle[2]

1% to 99%

0.1 %

[1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA

[2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range).

[3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified.

[4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %.

LED Test and Continuity Threshold

Function

Lighting Range

Measurement Range

Resolution

Accuracy

LED VF Test[1]

(LED Test Socket)

1.00 to 6.00 V

NA

NA

NA

LED VF Test[2]

( Test leads)

1.00 to 6.00V

1.00 to 6.00V

0.01V

NA

NA

NA

NA

[1] Open circuit test voltage is±12V and short-circuit current is<±5mA(typical)

[2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical)

[3] VF Measurement with driving current under2.2±0.4 mA

Input Protection

Input Impedance

(Nominal)

Common Mode

Rejection Ratio

Normal Mode

Rejection Ratio

AC dB at dc,

50Hz or 60Hz

_

AC at dc,

50Hz or 60 Hz

_

DC at dc,

50Hz or 60 Hz

>60dB at

50Hz or 60 Hz

DC at ac,

50 Hz or Hz

_

[1]106V Hz Max

Closer Look: Package Includes:1 x Fluke 18B+ Multimeter1 x A Pair of Original Test leads1 x User manual Payment
  • We accept bothPaypalandCredit card(what no Paypal account needed). They are easy and safety what you need is only a credit card.
  • Please make payment within5 dayswhen you offer or sale ended.
  • PleaseDO NOToffer if you areNOTintend to buy. For unpaid item more than 5 days,Unpaid dispute & the Negative responsewill be filed to for the non payable buyers.
Shipping & Delivery
  • All products will be sent within48 hoursafter your Paymet received except Sunday (GMT+8).
Contact Us
  • Welcome!! Please readALL POLICIESof us before your purchase.
  • If you have additional questions or concerns about this item, please contact us via email.We will response the most E-mail within24hours(9:00-18:00 GMT+8 Monday-Friday).
  • They Message through could be marked asSpamsometimes. Please check Spam folder of your Email Box first, if you haven\'t received our response after 72 hours.
Return Policy
  • If the item is defective, please notify us within 7 days after the receipt of the item.
  • The item shall be return in its original condition, in order to get it refunded or replaced.
response
  • You will get aPOSITIVE responseafter you paid.
  • Your satisfaction andresponseisVERYimportant to us. If you have questions regarding your order, or if you feel that have a problem with order, pleasecontact usfor a resolution before leaving response. We appreciate the opportunity to have a fair transaction.


Buy Now

Related Items:

Powered by WordPress. Designed by WooThemes